CellDrop Assays | Accessories | Codes

Quick Order with Visa/Mastercard/AMEX

(US Customers Only)

AO/PI Viability Assay

The Acridine Orange (AO) / Propidium Iodide (PI) assay is used for cell counting and viability. AO is a nucleic acid-binding fluorophore that is cell membrane permeable and suitable for selective staining of nucleated cells. PI is a nucleic acid-binding dye that is impermeable to live cells and suitable for staining dead, nucleated cells. All live, nucleated cells fluoresce green due to AO, while dead, nucleated cells are stained with both AO and PI and fluoresce red. Available in 300 assay or 1500 assay quantities.

SKU: K-30520
Components – 1.5 mL (300 assays) @ mix of 5 ug/mL AO+ 100 ug/mL PI in PBS

SKU: K-30530
Components – 7.5 mL (1500 assays) @ mix of 5 ug/mL AO+ 100 ug/mL PI in PBS

AO/PI Viability Assay for CellDrop: Select size (assays in kit)

Acridine Orange

The Acridine Orange (AO) Dye is used for total cell counting. AO is a nucleic acid-binding fluorophore that is cell membrane permeable and suitable for selective staining of nucleated cells.

SKU: K-30500

Components 1.5 mL @ 10 ug/mL in PBS

300 Assays

Acridine Orange Dye for CellDrop

Propidium Iodide

The Propidium Iodide (PI) Dye is used for viability assessment. PI is a nucleic acid-binding dye that is impermeable to live cells and suitable for staining dead, nucleated cells.

SKU: K-30570

Components 1.5 mL @ 100 ug/mL in PBS

300 Assays

Propidium Iodide Dye for CellDrop

Yeast

The Fluorescein Diacetate (FDA) and Propidium Iodide (PI) assay is used for yeast cell viability testing. FDA is a cell viability probe that is membrane-permeable to live yeast cells. Inside a live cell, FDA is cleaved to give fluorescein by the action of intracellular esterases. Propidium Iodide dye for viability assessment. PI is a nucleic acid-binding dye that is impermeable to live cells and suitable for staining dead, nucleated cells. Live cells are reported by FDA in the green channel, dead cells by PI in the red channel.

SKU: K-30590

Components 300 uL PI, 300 uL FDA, 25 mL PBS buffer

300 Assays

Yeast Viability Assay Kit for CellDrop

Trypan Blue

The Trypan Blue (TB) dye is used for brightfield viability assessment. TB is an azo dye that is excluded from cells with intact cell membranes, only staining non-viable cells. The trypan blue assay is used to assess the number of viable cells present in a cell suspension.

SKU: K-30580

Components 1.5 mL @ 0.4% in PBS

300 Assays

Trypan Blue Viability Dye for CellDrop

Erythrosin B

Erythrosin B is a biosafe and non-toxic colorimetric dye that can be used as an alternative to Trypan Blue for cell counting and viability assessment. Evaluation of cell viability using Erythrosin B dye exclusion is based on a similar principle to Trypan Blue, that intact cell membranes exclude the polar molecules whereas compromised membranes do not. Live cells remain unstained while dead cells are stained and have a darker appearance.

SKU: K-30490

300 Assays

Erythrosin B Viability Dye for CellDrop

Count Codes for CellDrop Cell Counters

The Serial Number is required. Please include when placing your order.
The DeNovix team will process the order and email a count code within one business day. If you have an emergency requirement for additional counts, please call DeNovix at +1-302-442-6911 for immediate help, 9:00 am – 5:00 pm Eastern US time.

Count Code Options
Serial Number

Brightfield Beads for CellDrop

SKU: K-30540

Components 0.5 mL @ 1×106

50 Samples

Brightfield Beads for CellDrop

Fluorescence Beads for CellDrop (Fluorescence Models)

SKU: K-30550

Components 0.5 mL green / red mix @ 1×106

50 Samples

Fluorescence Beads for CellDrop

Accessories

 

DeNovix 20 µL Pipette

20 uL Pipette

Capacity 2.0 – 20.0 uL

Ergonomic design

 

DeNovix 20 uL Pipette

Performance Verification Slide

SKU: P-0528

The CellDrop PV Slide is used to confirm CellDrop accuracy and precision. The slide contains permanently mounted beads which are analyzed and labeled with a factory certified count and density. The slide can be used for validation of the brightfield, green fluorescence and red fluorescence channels. Factory validation certificate and storage case are included.

CellDrop Performance Verification Slide

Opticon USB Scanner OPI3601
BARCODEpng

> Rapidly scans/decodes a wide variety of 1D or 2D barcodes
> Customizable trigger modes
> Distinct targeting guides
> Auto-Trigger features both stand-alone and with stand detection

 

Opticon USB Scanner